Quick Guide
Activity 1: Determine the Reaction
Rate in the Presence or Absence
of an Enzyme
1. Find your 15 ml conical tubes labeled
“Stop Solution”, “1.5 mM Substrate”,
“Enzyme” and “Buffer”. Write your initials
on each tube.
2. Label five cuvettes E1–E5.
3. Label the two remaining cuvettes “Start”
and “End”.
4. Using a clean DPTP, pipet 500 µl of stop
solution into each labeled cuvette. Rinse
the DPTP well with water.
5. Label one empty 15 ml conical tube
“Enzyme Reaction” and the other
“Control”.
6. Using a clean DPTP, pipet 2 ml of 1.5 mM
substrate into the 15 ml conical tube
labeled “Enzyme Reaction”. Use the
same DPTP and pipet 1 ml of 1.5 mM
substrate into the conical tube labeled
“Control”. Rinse the DPTP well with
water.
7. Label one DPTP “E” for enzyme and the
other “C” for control. Only use the DPTP
labeled “E” for the enzyme reaction tube
and the DPTP labeled “C” for the control
reaction tube.
26
Quick Guide
QUICK GUIDE
Label up here
Stop Solution
1.5 mM Substrate ControlEnzyme reaction
Start
End
E1 E2
E3
E4 E5
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - Quick Guide

Quick GuideActivity 1: Determine the ReactionRate in the Presence or Absenceof an Enzyme1. Find your 15 ml conical tubes labeled“Stop Solution”, “1.5

Página 2

Quick GuideActivity 6: Test the Ability ofMushroom Extracts to Increasethe Reaction Rate1. Write down the name of your mushroom______________________

Página 3

7. Using a clean DPTP, pipet 500 µl of stopsolution into each cuvette. Rinse out theDPTP thoroughly with water.8. Label a 15 ml conical tube with th

Página 4

Life Science Group 10-0100 0210 Sig 11095947 Rev A US/EGBio-Rad Laboratories, Inc. Web site www.bio-rad.com USA 800 424 6723 Australia 61

Página 5

Read and understand steps 8–11 fullybefore proceeding. These steps are timesensitive!8. Using the DPTP labeled “C”, pipet 500 µlof buffer into the 15

Página 6

Quick GuideActivity 2: Determine the Effect ofTemperature on the Reaction Rate1. Label your cuvettes “0°C”, “22°C”, and“37°C”. 2. Using a clean DPTP

Página 7

6. Have a stopwatch ready. Using a cleanDPTP, pipet the 250 µl of enzyme fromthe tube labeled “0°C Enzyme” into thetube labeled “0°C Substrate”, and

Página 8

Quick GuideActivity 3: Determine the effect ofpH on the Reaction Rate1. Label your cuvettes “pH 5.0”, “pH 6.3”,and “pH 8.6”. 2. Using a clean DPTP,

Página 9

Quick GuideActivity 4: Determine the Effect ofEnzyme Concentration on theReaction Rate1. Label one 15 ml conical tube “LowConcentration Enzyme”. Usin

Página 10

Please read steps 5–7 fully before proceeding. These steps are time sensitive!5. Using the DPTP labeled with an “H”,pipet 250 µl of 1.5 mM substrate

Página 11 - QUICK GUIDE

Quick GuideActivity 5: Determine the Effect ofSubstrate Concentration on theReaction Rate1. Label one clean 15 ml conical tube “LowConcentration Subs

Página 12 - Laboratories, Inc

Please read and understand steps 7–9fully before proceeding. These steps aretime sensitive!7. Using a clean DPTP, pipet 750 µl ofenzyme into your 15

Comentários a estes Manuais

Sem comentários