17.3 Fitting the batteries and connecting the poles correctly
Caution!
Installation of Batteries
Effect: Damages to the machine
Always connect batteries with the correct polarity
3
1
2
4
Fig. 338:
To do this:
Connect the positive cable from the starter (3) to the positive pole of the battery (1).
Connect the positive cable of the battery (1) with the positive pole (30a) of the battery
changeover relay (4).
Connect the negative cable of the battery (1) with the negative pole (31a) of the battery
changeover relay (4).
Connect the negative cable from the starter (3) to the negative pole of the battery (2).
Connect the negative cable of the battery (2) with the negative pole (31) of the battery
changeover relay (4).
Connect the positive cable of the battery (2) with the positive pole (30) of the battery
changeover relay (4).