Error Messages
Possible cause Check Remedy
KMC1
Message Meaning
Run electronics diagnostics
KMC1 LD28 not lit
Short circuit in the wiring
to an analogue sensor
Check wiring
Analogue sensor defective Check the sensors and replace, if and
when necessary
Charge indicator lamp defective Check charge indicator lamp,
Check wiring
Dynamo defective
Check the excitation voltage, check the
1109 KMC1 voltage 8V
ana.sensors
Error: 8 V voltage of
analogue sensors
Dynamo defective
Check the excitation voltage, check the
wiring, replace the dynamo
Battery dead Charge battery, check battery acid,
replace battery
Internal error - KMC1 Replace KMC1
Run electronics diagnostics
Discharge the backup battery Replace the backup battery in KMC1
Internal error - KMC1 Replace KMC1
Performing axle suspension diagnostics
Short circuit/broken cable in the wiring Check wiring
Sensor defective Check sensor and replace, if and when
necessary
Internal error - KMC1 Replace KMC1
Error:
Backup battery voltage
3 V too low
KMC1 vlt. batt. 3V
too low
1110
Error: Position sensor
axle suspension
Sensor B20,
position axle
suspension
1200