Error Messages
Message Meaning Possible cause
SmartDrive
Limp modeCheck Remedy
Short circuit/broken cable in the wiring
for actuator valve 2 pump 2
Check wiring to actuator valve 2
for pump 2
Valve plug defective Replace valve plug
Coil for solenoid valves defective Replace coil
Internal SmartDrive error Replace SmartDrive
Short circuit/broken cable in the wiring
for stop valve pump 2
Check wiring to stop valve
for pump 2
Valve plug defective Replace valve plug
Coil for solenoid valve defective Replace coil
Internal SmartDrive error Replace SmartDrive
64 SmartDrive
current pump 2
coil 2 (Y3)
Error: Actuator valve 2
drive pump 2 – rear axle
backward
65 SmartDrive wiring
pump 2 coil 3
(Y46)
Error: Stop valve drive
pu
mp 2 – rear axle
Brake was applied continuously
(for example braking pressure greater
than 10 bar and longer than 3 min.)
Remove foot from the brake
Run travelling gear diagnostics
Brake valve defective or jammed Check brake valve
Brake pressure sensor defective Replace the brake pressure sensor
Internal SmartDrive error Replace SmartDrive
95 Error: Brake valve Error: Brake valve