Error Messages
Message Meaning Possible cause
SmartDrive
Limp modeCheck Remedy
The brake tank pressure is too low Start diesel engine so that the
accumulator is filled
Run travelling gear diagnostics
Accumulator charging valve defective Replace accumulator charging valve
Accumulator defective Replace accumulator
Short circuit/broken cable in wiring for
brake tank pressure sensor
Check the wiring to the brake tank
pressure sensor
Sensor plug for brake tank pressure
defective
Replace sensor plug
Sensor for brake tank pressure
defective
Replace brake tank pressure sensor
38 SmartDrive brake
tank pressure
(B25)
Error: Brake tank
pressure
too low
Internal SmartDrive error Replace SmartDrive