Error Messages
Possible cause Check Remedy
KMC1
Message Meaning
Hydr. cutting height activated even
though there is no hydr. cutting height
present
Deactivate hydr. cutting height
in display
Performing cutting height diagnostics
Short circuit/broken cable in the wiring Check wiring
Sensor defective Check sensor and replace, if and when
necessary
Internal error - KMC1 Replace KMC1
Hydr. cutting height activated even
Deactivate hydr. cutting height
Error: Cutting height
Sensor B41,
1302
Error: Cutting height
sensor right – signal out
of range
Sensor B42,
inclination mowing
unit right
1301
Hydr. cutting height activated even
though there is no hydr. cutting height
present
Deactivate hydr. cutting height
in display
Performing cutting height diagnostics
Short circuit/broken cable in the wiring Check wiring
Sensor defective Check sensor and replace, if and when
necessary
Internal error - KMC1 Replace KMC1
Error: Cutting height
sensor left – signal out
of range
Sensor B41,
inclination mowing
unit left
1302